• Darwin Motion +61 432112288    Darwin Motion +91 8956113099
  • Blogs
  • FAQ's
  • Testimonials
Logo
  • Home
  • About Us
  • Team
  • Data Sheets
  • Products
      Products
      • Micro Drive
        • Matrix-900

      • DR Matrix 350 / Solar Drive
        • Matrix 350 Products
      • HIGH FREQUENCY DRIVE - HF
        • DR Matrix 500

      • High Performance Drive
        • DR Matrix 680

      • Regenerative Drive
        • DR Matrix 880
  • Applications
      Applications
      • Engine & Motor Testing Dynamometer

      • Textile Machine
        • Textile Dying Machine

      • Winding Industry

      • VFD for Bar Mill
      • Extrusion Machine Haul-off Application

      • VFD for injection molding Machine

      • Spinning Machine Application

      • Multiple Pump VFD
      • Winding Industry
      • Extruders
      • Cross Cutter Metal Cutting
      • High Speed CNC Spindal Drive
      • TFO Machine Application
      • Tower Crane
      • Wire Drawing Machine
      • Flying Sheer

      Why Us?

      Our team of Designing Engineers has extensive experience spanning several decades in the research and development of automation technology.

  • AC Drives
      AC Drives
    • Active Front End VFD
    • Bi-directional Power Supply
    • VFD
    • Variable Frequency Drive
    • Servo Drive
    • High Frequency Drive
    • Profinet Communication Drive
    • EtherCAT Communication Drive
  • Certificates
      Certificates:
    • CE UKCERT EMC
    • ROHS UKCERT
    • ISO 9001
  • catalogue
  • contact

Solar Drive

  • Home
  • AC Drives
  • Matrix- 180
  • Overview
  • Introduction
  • Key Features
  • Applications
  • Advantages
  • Drive Configuration
  • Documentation
DR Matrix 180(A) T1D5 - 1.5 KW
Variable Frequency Drive
3PH AC 380-440 V | 50-60 Hz
3PH 3PH AC 380-440V | 0-999 Hz
    Find the energy efficiency data for your drive

Introduction

Darwin Motion Vector & torque control frequency converter adopts advanced current vector control technology. It has the function of full frequency band high torque output and fast response, excellent load adaptability, high speed control accuracy and good reliability. It is an ideal choice for Open Loop & Closed Loop frequency converter to meet high field requirements.

Key Advantages

  • Significant energy saving effect the mechanical energy generated by the prime mover is converted into electrical energy and fed back to the grid.
  • Good two-way loading characteristics Provide two-way consistent loading capacity to adapt to the power mechanical test of different steering.
  • Superior low-speed loading capacity Basically, the rated load torque can be provided from zero speed (encoder required).
  • High-speed torque response speed the torque response speed of the electric dynamometer can reach the ms level, which is used in the simulated load and new energy industries.
  • Provide anti-drag ability The electric dynamometer can be used as a power source, such as mechanical efficiency power drive, generator power drive
  • Multiple protection functions Provide multiple protection functions such as phase loss, overvoltage, overcurrent, overspeed, etc. to protect the dynamometer and test pieces

OUR VFD DRIVE APPLICATIONS:

  • Agriculture
  • Material Handling
  • Cranes & Hoists
  • Mining
  • Food & Beverages
  • Printing
  • General Automation
  • Refrigeration & Air Conditioning
  • HVAC
  • Solar Pump
  • Leisure
  • Pumping
  • Lifts/elevators
  • Textiles & Paper
  • Marine
  • Water & Wastewater
  • Fan
  • Winder
  • Unwinder
  • Blower
  • Conveyors
  • Flying Shear
  • Extruders
  • Injection Moulding

Advantages:

  • Free selection of the network pressure:The network pressure can be adjusted between 5 and 13 bar
  • Constant network pressure: Independent of the air demand the network pressure can be kept constant through
  • the speed variation In this way the maximum pressure can be reduced and energy can be saved Example: A reduction of the maximum pressure of about 1 bar gives energy reductions of about 6-8 % in relation of the total power consumption of the compressor
  • Energy Saving By Drawin drives - Energy savings are achieved through: Avoiding unload operation and resultant energy wastage
  • Constant near unity power factor resulting in lesser peak kva demand
  • Optimum efficiency of motor operation resulting in energy saving
  • No starting and Delta/Start switch over currents resulting in lesser stress on electrical system
  • Exact delivery volume resulting in smooth operation as required
  • Free selection of the network pressure resulting in flexibility
  • Constant network pressure resulting in system efficiency

Drive Configurator

Type Power Power Supply Output Current External Dimensions
DR Matrix180 S0D4 0.4KW Single phase 220-240VAC 50/60Hz Three phase 220-240VAC 50/60Hz 2.3 186.5*86*143.5
DR Matrix180 S0D7 0.75KW Single phase 220-240VAC 50/60Hz Three phase 220-240VAC 50/60Hz 4186.5*86*143.5

Type of Variable Frequency Drive
DR Matrix180 S1D5 1.5KW Single phase 220-240VAC 50/60Hz Three phase 220-240VAC 50/60Hz 7 186.5*86*143.5
DR Matrix180 S2D2 2.2KW Single phase 220-240VAC 50/60Hz Three phase 220-240VAC 50/60Hz 9.5 186.5*86*143.5
DR Matrix180 S3D 3KW Single phase 220-240VAC 50/60Hz Three phase 220-240VAC 50/60Hz 13  
DR Matrix180 S4D 4KW Single phase 220-240VAC 50/60Hz Three phase 220-240VAC 50/60Hz 15  
DR Matrix180 S5D5 5.5KW Single phase 220-240VAC 50/60Hz Three phase 220-240VAC 50/60Hz 20  
DR Matrix180 T0D4 0.4KW Three phase 380-440VAC 50/60Hz 1.5 186.5*86*143.5
DR Matrix180 T0D7 0.75KW Three phase 380-440VAC 50/60Hz 2.5 186.5*86*143.5
DR Matrix180 T1D5 1.5KW Three phase 380-440VAC 50/60Hz 4.1 186.5*86*143.5
DR Matrix180 T2D2 2.2KW Three phase 380-440VAC 50/60Hz 5.1 186.5*86*143.5
DR Matrix180 T3D 3KW Three phase 380-440VAC 50/60Hz 7.9 186.5*86*143.5
DR Matrix180 T4D 4KW Three phase 380-440VAC 50/60Hz 9.4  
DR Matrix180 T5D5 5.5KW Three phase 380-440VAC 50/60Hz 12.6  
DR Matrix180 T7D5 7.5KW16.1 

Documentation:

Name Country/Language Download File Type
Technical Catalogue English PDF
Technical Specification English PDF
protocols
protocols
protocols
protocols
protocols
protocols
protocols
protocols
protocols
protocols

About

  • Darwin Motion

    Email : sales@darwinmotion.com

  • Darwin Motion

    Darwin Motion, Office No - 212 Xion Pacific , Hinjewadi Pune Maharashtra India 411057

  • Darwin Motion

    Darwin Motion, Suite 379 Level 2/66 Victor Crescent NARRE WARREN VIC 3805

AC Drives

  • Micro Drive- Matrix 900
  • DR Matrix 350 / Solar Drive
  • DR Matrix 500
  • DR Matrix 680
  • DR Matrix 880

Blogs

  • VFD
  • Servo Drive
  • High Frequency Drives
  • Profinet Comunication Drives
  • EtherCAT Communication Drives

Quick Enquiry

Call Us Today

Darwin Motion +91 8956113099
Darwin Motion +61 432112288

Opening Hours

  • Mon - Sat :
    10.00 am - 7.00 pm
  • Sun :
    Closed

Factory Address:

    Darwin Motion Gat no 309,ne bapdev mandir nighoje, Chakhan, Pune, Maharashtra 410501

© Copyright 2019. All Rights Reserved by Darwin Motion

  • Terms of use
  • Privacy & Policy
  • FAQ's
  • Blogs
  • Darwin Motion Matrix VFDs